The code mandate was later expanded to include any receptacles in a laundry room in the 2014 nec.
Gfci required in laundry room.
Gfci protection is required for 125 volt to 250 volt receptacles supplied by single phase branch circuits rated 150 volts or less to the ground.
Gfci receptacle outlets electrical question.
See the nec code requirements in the table below for more specific information.
Occupancy controlled lighting will be required too.
Now let s refer to nec 2017 section 210 8 for the answer to the gfci portion of our question.
Although the code does not specifically state that a washing machine receptacle has to be gfci the washing machine must have water service and a drain so its location becomes defined as a laundry.
Receptacles within 6 feet of a laundry sink were first required to be gfci protected by the 2005 edition of the national electrical code nec.
2005 does require gfci 6 from laundry sinks.
According to the nec a gfci is required if the power outlet is within 1 8 meter radius from the water source.
The requirement for gfci protection in laundry areas was deleted.
Because by definition where the washing machine is located becomes the laundry the two phases of this requirement meant that initially a washing.
Gfci stands for ground fault circuit interrupter.
This circuit can supply a clothes washer or a gas dryer.
If the laundry room does not have a window then an exhaust fan will be required along with a switch.
All receptacles must be gfci protected.
It s a device that protects people from receiving shocks from faults in an electrical system.
Where gfci protectio n is required.
Yes as of the 2017 edition of the national electrical code nec any receptacles in a laundry room must be gfci protected.
The requirement for afci protection in kitchens and laundry areas as well as for branch circuit extensions or.
A laundry room needs at least one 20 amp circuit for receptacles serving laundry equipment.
The only wiggle room for the washing machine is if it drains into a standpipe drain and there is no sink.
The nec doesn t require gfci protection for clothes washing machines specifically but it does for laundry areas.
Gfci receptacles monitor any electric current imbalance between the circuit s hot and neutral conductor and shuts of the circuit if an imbalance is present.
Gfci receptacles are required in bathrooms garages crawl spaces basements laundry rooms and areas where a water source is present.
210 8 a 10 all 125v 15a and 20a receptacles installed in laundry areas shall have gfci protection.
If the water supply is permanently connected to washing machines in a laundry area does it require a class a gfci protected receptacle.