First of all just check and make sure your unit was not accidentally switched to a c mode.
Goodman heat pump thermostat not working.
Raise the set temperature 5 degrees f.
No cold and no heat.
In case your heat pump is not working at all the problem is usually with the unit receiving power or with the thermostat.
Heat pumps look similar to air conditioners so check the label on your outdoor unit to make sure it s a heat pump.
All the correct 24 volts are coming to the five wires coming from the air handler to the heat pump.
If your home has a heat pump the thermostat or control system should be able to control the auxiliary heat function.
Blowing cold in heat mode.
As the name suggests the reversing valve allows the heat pump to work as both a heater and an air conditioner by reversing the direction of the refrigerant.
My goodman heat pump is not working the fan and the compressor.
There is no 24 volts on the yellow wire on the defrost control board that leads to the.
3 check the heat pump.
It will also need to be replaced by a technician.
Here is what you need to do.
The compressor pumps a refrigerant gas to dehumidify and cool the air.
Goodman heat pump won t run.
Over time the compressor unit in the goodman central air system may fail.
If not your system may have a valve problem a refrigerant charge issue or a compressor problem.
If it is specific to a gas furnace you may not be able to control this function.
If the heat pump turns on when you want cool air but not for heat this is likely the cause.
And then wait a few minutes for the heat to come on.
There are the descriptions for different goodman modifications gpc1336m41 r 410a and n2h3.
Next check your outdoor unit is not iced over see heat pump troubleshooting problem 1.
It also removes heat and moisture from the air inside your home by circulating the warm air over the indoor coil and pumping it to the outside of your home and pumping the cool air inside.
If you have a dual fuel system you will need to have a trained professional set up your thermostat.
If the heat does not come on even when the thermostat is set above room temperature then you probably have a blown fuse or a tripped circuit breaker.
The tables below are the lists of possible issues which you may encounter having goodman heat pump not working.
2 be sure the room heating registers are open.
Heat pump troubleshooting problem 3.
If you re still not sure which system you have contact a local pro.
There is 24 volts on the yellow wire connected to the fan capacitor.
Heat pump not heating.